Basic Info.
Model NO. | M01 two wires and reverse polarity | Connection Form | Thread |
---|---|---|---|
Driving Mode | Electric | Nominal Pressure | PN1.0-32.0MPa |
Channel | Straight Through Type | Structure | Flexible Ball Valve |
Type | Flexible Ball Valve | Function | Control Flow Valve |
Temperature | Normal Temperature | Application | Industrial Usage, Water Industrial Usage, Household Usage |
Ambient Temperature | 15-50 Celsius | Working Temperature | 0-90 Celsius |
Working Pressure | 10 Bar Max. | Open/Close Time | 5 Sec. |
Rated Protection | IP67 | Nominal Voltage | AC230V Working Current 0.5 AMPS |
Certificate | ISO, CE;Atex | Specifications | Compact Design Light Weight Small Actuator with Fa |
Valve Diameter | DN20 | Actuator Voltage | DC5V DC12V |
Transport Package | Bubble Wrap Plus Carton | Specification | DC12V 24V AC110 220V 380V |
Trademark | LEADWIN | Origin | China |
Production Capacity | 3000piece/Day |
Packaging & Delivery
Package Size | 10.00cm * 10.00cm * 16.00cm | Package Gross Weight | 1.200kg |
---|---|---|---|
Lead Time |
15 days (1 - 1000 Pieces)
To be negotiated ( > 1000 Pieces) |
Product Description
Mini Electric Ball ValveCompact design and light weight, small electrical actuator with fail-safe function (NC/NO)
![]() |
INSTRUCTION FOR MANUAL OVERRIDE | |||
It is only permitted to use when power-off | ||||
![]() |
Lift the hand-wheel,and turn it left or right until the valve is in place | |||
When the black line on the indicator is horizontal,the valve is on;when vertical,the valve is off | ||||
Press down hand-wheel after using manual override in order to work properly when power-on | ||||
CE | IS09001 |

FEATURES | APPLICATION | |||
Mini dimension suit for small equipment | HVAC | |||
Patented technology-floating seal structure | Water treatment | |||
Long service life:80000 to 100000 cycles | Chemical process | |||
Low working current,suitable for battery driving | Small equipment for automatic Control | |||
Manual override and position indicator | Replacing solenoid valve, particularly when solenoid can't work reliably |
|||
Metal gearbox and POM gear | ||||
High flow capability | ||||
PARTS | MATERIAL | |||
![]() |
||||
![]() |
Actuator housing |
ABS | ||
Valve body | Brass/SS304 | |||
Valve ball | Brass/SS304 | |||
Stem | Brass/SS304 | |||
Ball seat | PTFE | |||
Seal | SILASTIC(Q) |
TECHNICAL PARAMETERS | ||||||||
Series | Max torque |
Operating time |
Working voltage |
Max power |
Enclosure | Max pressure |
Medium temperature |
Ambient temperature |
FH-MO | 2.5N,m | <5sec<> | DC3-V | <5w<><5sec<> | IP65 | 1.0Mpa | 0-90ºC | -20ºC |
AC/DC9-24V |

M01 (two wires and reverse polarity)
Voltage: DC6V/12V

M02 (three wires two point control)
Voltage: DC6V/12V/ 9-35V

2.Connection SW to CLOSE, the valve closes , getting the position, automatically power off, the valve remains side passes position(fully closed).
M03 (three wires one control)
Voltage: DC6V/9-35V AC/DC9-24V

2.Disconnecting SW, the valve close, getting the position, automatically power off, the valve remains side passes position(fully
M04 (two wires and fail-safe/power-off return)
Voltage: DC6V/9-35V AC/DC9-24V

2.SW disconnecting, the valve close, getting the position and power off automatically, the valve remains fully open/close position.
M05 (five wires with signal feedback and Internal automatic power off function)
Voltage: DC6V/12V

2.BK connect with positive, the RD connect with negative, the valve close, the actuator automatically power off after in place .
3.YW & WT are connect when the valve open fully, GR & WT are connect when the valve closed fully.
M06 (six wires with signal feedback and two point control)
Voltage: DC6V/12V

2. When RD & SW connected, the valve open, the actuator automatically power off after the valve fully open.
3. When GR & SW connected, the valve closed, the actuator automatically power off after the valve fully closed.
4. YW & WT connect with the valve's fully open signal wiring.
5. BL & WT connect with the valve's fully closed signal wiring.
M07 (six wires with signal feedback and one point control) Voltage: DC6V/12V/ 9-35V

- RD connect with positive, GR connect with SW and negative wiring, BK connect with negative wiring.
- SW open, the valve open, and keeping fully open. SW closed, the valve closed, and keeping fully closed.
M08 (five wires with signal feedback and fail-safe/power-off return function)
Voltage: DC6V/9-35V AC/DC9-24V

3.YW & GY connect with the valve's fully open signal wiring. BL & WT connect with the valve's fully closed signal wiring. Unique FAQs
Retrofitting Valve Electric Actuators:
- Many are retrofit-friendly. Consider compatibility, sizing, and necessary modifications. Consult experts for guidance.
Preventing Leaks and Spills:
- Provide precise control to enhance safety and reduce environmental risks in industrial processes.
Advancements in Remote Monitoring:
- Smart actuators with connectivity enable remote monitoring and control, improving flexibility and efficiency.
Process Optimization:
- Precise fluid flow control enhances efficiency, ensures consistent quality, and reduces waste in manufacturing.
Cybersecurity Measures:
- Robust security measures, including encryption and authentication, protect against cyber threats and unauthorized access.