• Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation
  • Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation
  • Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation
  • Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation
  • Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation
  • Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation
  • Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation
  • Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation
  • Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation
  • Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation
  • Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation
  • Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation

Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation

Mini Smart 24V DC Plastic Pph Double Union Motorized Water Control Ball Valve with Electric Actuator Plumbing Irrigation

free quote

Basic Info.

Model NO.m-02Connection FormThread
Driving ModeElectricNominal PressurePN1.0-32.0MPa
ChannelStraight Through TypeStructureFlexible Ball Valve
TypeFlexible Ball ValveFunctionControl Water Gas Oil Ect Flow Valve
TemperatureNormal TemperatureApplicationIndustrial Usage, Water Industrial Usage, Household Usage
Ambient Temperature15-50 CelsiusWorking Temperature0-90 Celsius
Working Pressure10 Bar Max.Open/Close Time5 Sec.
Rated ProtectionIP67Nominal VoltageAC230V Working Current 0.5 AMPS
SpecificationsCompact Design Light Weight Small Actuator with FaSize1/2in 3/4in 1in
PressureMedium PressureTransport PackageBubble Wrap Plus Carton
SpecificationDC12V 24V AC110 220V 380VTrademarkLEADWIN
OriginChinaProduction Capacity3000piece/Day

Packaging & Delivery

Package Size10.00cm * 10.00cm * 20.50cmPackage Gross Weight1.200kg
Lead Time 15 days (1 - 1000 Pieces)
To be negotiated ( > 1000 Pieces)

Product Description


Mini Electric Ball Valve
Compact design and light weight, small electrical actuator with fail-safe function (NC)
Product Description


2
WIRING DIAGRAM
                  CR201   WIRING   DIAGRAM(2   WIRES   CONTROL)
RD connect with positive,the BK connect with negative,the valve closed, the actuator automatically power off after in place,the valve remains fully closed position.
·BK connect with positive,the RD connect with negative,the valve open, the actuator automatically power off after in place,the valve remains fully open position
*Suitable Working Voltage:DC5V,DC12V,DC24V
*Exceeding the working voltage is forbidden
RD:Red wire BK:Black wire GR:Green wire BL:Blue wire
    CR202 WIRING DIAGRAM
(2 wires control-"Capacitors return"in case of the power is failure)
·When SW is CLOSED,the valve OPEN,the actuator automatically power off after in place.
·When SW is OPEN,the valve CLOSED,the actuator automatically power off after in place.
*Suitable Working Voltage:DC5V,AC/DC9-24V,DC9-35V,AC110V-230V
*Exceeding the working voltage is forbidden
                  CR301 WIRING DIAGRAM (3 WIRES CONTROL)
·RD&GR connect with positive,BK connect with negative
·When RD&SW connected,the valve open,the actuator automatically power off after in place,valve remains fully open position
·When GR&SW connected,the valve closed,the actuator automatically power off after in place,valve remains fully closed position.
*Suitable Working Voltage:DC5V,DC12V,DC24V
*Exceeding the working voltage is forbidden
CR302 WIRING DIAGRAM (3 WIRES CONTROL)
RD connect with positive,the BK &GR connect with negative
·SW CLOSED,the valve OPEN,the actuator automatically power off after in place
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place.
*Suitable Working Voltage:DC9-35V
*Exceeding the working voltage is forbidden
CR303 WIRING DIAGRAM (3 WIRES CONTROL)
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve OPEN,the actuator automatically power   off after in place.
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place.
*Suitable Working Voltage:AC/DC9-24V,DC9-35V,AC110-230V
*Exceeding the working voltage is forbidden
CR304 WIRING DIAGRAM (3 WIRES CONTROL )
·RD&GR connected with positive,and the BK connected with negative
·When RD&SW connected,the valve closed,the actuator automatically
power off after in place,remains fully closed position
·When GR&SW connected,the valve open,the actuator automatically power off after in place,remains fully open position.
*Suitable Working Voltage:DC5V,DC12V,DC24V
*Exceeding the working voltage is forbidden
    CR305 WIRING DIAGRAM
(3 wires control-"Capacitors return"in case of the power is failure)
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve OPEN,the actuator automatically power off after in place.
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place.
*The valve will be auto closed when power is failure.
*Suitable Working Voltage:AC/DC9-24V,AC110-230V
*Exceeding the working voltage is forbidden
CR306 WIRING DIAGRAM
(3 wires control-"Capacitors return"in case of the power is failure)
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve CLOSED,the actuator automatically power off after in place
·SW OPEN,the valve OPEN,the actuator automatically power off after in place.
*The valve will be auto closed when power is failure.
*Suitable Working Voltage:AC/DC9-24V,AC110-230V
*Exceeding the working voltage is forbidden
CR401 WIRING DIAGRAM (4 WIRES CONTROL)
1,RD&BK are connected to the power,GY&GR are connected to the
controlled wiring,
2,When the SW is closed,the valve open
3,When the SW is open,the valve closed
*Suitable Working Voltage:AC110V-230V
*Exceeding the working voltage is forbidden
The control wiring with power DC5V/DC24V,when muitiple motorized valves are working in paralled,must put the same color control wiring together,otherwise the valve could working
CR501 WIRING DIAGRAM(WITH FEEDBACK SIGNAL)
1.RD connect with positive,the BK connect with negative,
the valve closed,the actuator automatically power off after in place.

2.BK connect with positive,the RD connect with negative,
the valve open,the actuator automatically power off after in place.
3.GR&WT are connect when the valve open fully,YW&WT
are connect when the valve closed fully
*Suitable Working Voltage::DC5V,DC12V,DC24V
*Exceeding the working voltage is forbidden!
   CR502 WIRING DIAGRAM
(with feedback signal and"Capacitors return"in case of the power is failure)
·When SW is closed ,the valve open.the actuator automatically power off after in place
·When   SW   is   open,the valve   closed,the   actuator automatically power off after in place
*GR&WT are connect when the valve open fully,YW &WT are connect when the valve closed fully
*Suitable     Working     Voltage:AC/DC9-24V,DC9-35V,AC110V-230V
*Exceeding the working voltage   is forbidden
   CR701 WIRING DIAGRAM
    (7 wires control with feedback signal)
---RD connect with positive
---GR connect with SW and negative wiring
---BK connect with negative wiring
---SW open.the valve open,and keeping fully open.
---SW closed.the valve closed,and keeping fully closed
----BL&GY connect with the valve's fully open signal wiring
---YW&WT connect with the valve's fully closed signal wiring
*Suitable Working Voltage:DC7-35V (wide input range voltage)
*Exceeding the working voltage is forbidden
Feedback with load ability:
The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A
   CR702 WIRING DIAGRAM
(7 wires control with feedback signal )
---RD connect with positive
---GR connect with SW and negative wiring
---BK connect with negative wiring
---SW open.the valve open,and keeping fully open.
---SW closed.the valve closed,and keeping fully closed.
----BL&GY connect with the valve's fully open signal wiring
---YW &WT connect with the valve's fully closed signal wiring.
*Suitable Working Voltage:DC7-35V (wide input range voltage)
*Exceeding the working voltage is forbidden
Feedback with load ability:
The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A
   CR702   WIRING   DIAGRAM
(7 wires control with feedback signal)
---RD connect with positive
---GR connect with SW and negative wiring
---BK connect with negative wiring
---SW open.the valve open,and keeping fully open.
---SW closed.the valve closed,and keeping fully closed.
---BL&GY connect with the valve's fully open signal wiring
---YW &WT connect with the valve's fully closed signal wiring.
*Suitable Working Voltage:DC7-35V (wide input range voltage)
*Exceeding the working voltage is forbidden
Feedback with load ability:
The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A
CR703   WIRING   DIAGRAM
(7 wires control with feedback signal)
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve OPEN,the actuator automatically power
off after in place
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place.
·BL&GY connect with the valve's fully open signal wiring
·YW&WT connect with the valve's fully closed signal wiring.
*Suitable Working Voltage:AC/DC9-24V,DC9-35V
*Exceeding the working voltage is forbidden
CR704   WIRING   DIAGRAM
(7 wires control with feedback signal)
·RD&BK are connected to the power,GR&BL are connected to the controlled wiring.
·When the SWis closed,the valve open
·When the SW is open,the valve closed
·GR&WT connect with the valve's fully open signal wiring
·YW&WT connect with the valve's fully closed signal wiring.
Suitable Working Voltage::AC110V-230V
*Exceeding the working voltage is forbidden
CR705   WIRING   DIAGRAM
(with feedback signal and"Capacitors return"in case of the power is failure)
·RD&GR connect with positive,the BK connect with negative.

·SW CLOSED,the valve OPEN,the actuator automatically power
off after in place.
·SW OPEN,the valve CLOSED,the actuator automatically power
off after in place.
·When external power is off,the valve closed,the actuator automatically
power off after in place.
·BL&GY connect with the valve's fully open signal wiring
·YW&WT connect with the valve's fully closed signal wiring.

*Suitable Working Voltage:AC/DC9-24V,AC110-230V

*Exceeding the working voltage is forbidden
CR706   WIRING   DIAGRAM
(with feedback signal and"Capacitors return"in case of the power is failure)
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve CLOSED,the actuator automatically power
off after in place.
·SW OPEN,the valve OPEN,the actuator automatically power
off after in place.
·When external power is off,the valve closed,the actuator automatically
power off after in place.
·BL&GY connect with the valve's fully open signal wiring
·YW&WT connect with the valve's fully closed signal wiring.

*Suitable Working Voltage:AC/DC9-24V,AC110-230V

*Exceeding the working voltage is forbidden

About the"Capacitors return"function,there are twokinds of valve:normally closed and normally open.
Normally closed:

the valve will be auto closed when the power is off(without power);the valve will be auto open when the power is on.
Normally open:
the valve will be auto open when the power is off(without power);the valve will be auto closed when the power is on.
Kindly Remind:
please charge the motorized ball valve before using. Unique FAQs
  1. Can valve electric actuators be retrofitted to existing systems?

    Yes, many valve electric actuators are designed for easy retrofitting. It's important to assess compatibility, sizing, and any necessary modifications to ensure smooth integration. Consulting manufacturers and experts can help identify the best retrofitting options.

  2. What role do valve electric actuators play in preventing leaks and spills in industrial processes?

    Valve electric actuators provide precise control, which is essential for preventing leaks and spills. By accurately modulating valve positions, they enhance the safety and integrity of industrial processes, reducing the risk of environmental incidents.

  3. Are there advancements in remote monitoring and control of valve electric actuators?

    Yes, advancements in technology have improved remote monitoring and control of valve electric actuators. Smart actuators with connectivity features enable operators to monitor and adjust valves remotely, boosting operational flexibility and efficiency.

  4. How do valve electric actuators contribute to process optimization in manufacturing plants?

    They optimize processes by offering precise fluid flow control, which enhances efficiency, ensures consistent quality, and minimizes waste in manufacturing operations.

  5. What measures are in place to ensure the cybersecurity of smart valve electric actuators?

    To protect against cyber threats, manufacturers implement strong security measures such as encryption and authentication protocols, ensuring the cybersecurity of smart valve electric actuators.

get quote
Request A Quote

Your privacy is our priority. Feel confident sharing your message and contact details with us.

contact now